Joel S.
Joel S. Checked in
AC performance tune up times one system. Clients change their own filter. Inspect blower, evaporator and ductwork. Found a wire to power thermostat from the furnace instead of from the batteries. Check outdoor unit. Refrigerant level good at this time. Wash condenser coil. System is cooling at manufacturer specs at this time.
The Colony, TX 75056
Joel S.
Joel S. Checked in
I was here earlier on a complimentary maintenance. Mark decided he would like me to return to add the refrigerant that I had recommended. If Mark says yes to the estimate that I left him I will apply the r22 towards the invoice for the new system.
The Colony, TX 75056
Joel S.
Joel S. Checked in
AC performance tune up times two systems. Mark changes his own filters. Inspect blowers, evaporators and ductwork. Downstairs is a 2021 model. I performed a leak search on both systems. Unfortunately both units are low on refrigerant. Downstairs is the newer r410a upstairs is r22 I am leaving a repair estimate in order to get the systems running at peak performance with refrigerant. Also leaving quotes for replacement for the upstairs since it is 14 years old.
The Colony, TX 75056
Russ T.
Russ T. Checked in
Fall heater maintenance one system heat pump (upstairs only). Upon arrival the system was turned on in emergency heat mode. At the indoor unit the blower motor, evaporator coil, heat strips, duct work, and electrical connections were all inspected. The system was then turned on in heat mode and at the outdoor unit the compressor, fan motor, condenser coil, electrical connections, and refrigerant charge were all inspected. The filter was changed with one provided by the homeowner. The system is heating properly at this time.
The Colony, TX 75056
Joel S.
Joel S. Checked in
Heat performance tuneup times one system. Changed out filter. Client supplied. Inspect blower, evaporator and thermostat. Checked outdoor unit. Tested defrost cycle. Wash condenser coil. Refrigerant is good at this time. System is heating properly at this time.
The Colony, TX 75056
Nicholas S.
Nicholas S. Checked in
The primary drain line was clogged, a blow out of the line with nitrogen later and the system began to drain normally. No other issues found at this time. See attached pictures.
The Colony, TX 75056
Review
Except being on the good contractors list, you should be on the good sales man list as well. Gave no alternative choices on fixing the unit, just a sell pitch on a unit. Feel bad for the good contractors list, This technician or should I say that company, can install and put in a brand new unit and probably to a great job. But when it comes to alternatives, brand new is the only language this company understands.
Eulogio - The Colony, TX 75056
Joel S.
Joel S. Checked in
Dispatch for no cool downstairs. Arrived fine system low on refrigerant again. Bob put in 12 pounds back in September. His note stated that they recommended I evaporator coil and secondary pans. I advise clients to make an appointment to get the maintenance done and we can do a leak search then. System is cooling at this time I left a quote for a coil and a new system. # NO
The Colony, TX 75056
Justin S.
Justin S. Checked in
Heat tune up on new heatpump . Sent tune up form to customer along with a quote for a duct cleaning.
The Colony, TX 75056
Review
Justin was quick and thorough, exactly on time (and let me know he was on the way) and explained everything he did completely! I really appreciate the excellent service he provided and the outstanding service I ALWAYS get from AC Pros. Consistency and dependability are truly invaluable and I very much appreciate it!!
Vicki - The Colony, TX 75056
Justin S.
Justin S. Checked in
Changed filter and completed heat maintenance and sent customer an email of everything checked .
The Colony, TX 75056
Samuel H.
Samuel H. Checked in
Apon arrival checked in with customer the following are my findings Found the unit working properly it is a year old only recommendation is continual maintenance please see pictures attached and estimate
The Colony, TX 75056
Justin S.
Justin S. Checked in
Installed thermostat for customer and got the temporary one I left back .
The Colony, TX 75056
Justin S.
Justin S. Checked in
Bad float switch and thermostat. Had one from another customers that I temp put on . Sill return to install new stat they get and get this t6 back
The Colony, TX 75056
Bob E.
Bob E. Checked in
Maintenance X3. I cleaned and serviced all three Systems. The Main System for downstairs’ is not cooling. I evaluated the defective System and found it to be VERY low on Refrigerant R-410A. I HIGHLY recommend replacing the Evaporator Coil and Secondary Drain Pan for the Downstairs’ System. Or the entire System. The existing System is a approximately 11-Year old 3.5-Ton Lennox R-410A A/C with matching Lennox Horizontal Gas Furnace with matching Coil. All three Secondary Drain Pans have Considerable rust and should be replaced and upgraded. The price to repair and replace all three Drain Pans is $1359.60.
The Colony, TX 75056
Review
I don’t work with any other vendor in any field who has this exceptional level of communication, follow up, and great service!! I can’t say enough about how much I appreciate the excellent workmanship and quality provided by Joel and AC Pros!!!
Vicki - The Colony, TX 75056
Joel S.
Joel S. Checked in
AC performance tune-up times one system. Inspect blower, evaporator and ductwork. Advised Vicky that the filter needs to be changed. She said she would get one today and have them here when we do her fall maintenance. Thermostat for proper operations. Check outdoor unit. Refrigerant level good at this time. Check capacitor and contactor. Wash condenser coil. System cooling properly at this time.
The Colony, TX 75056
Jeff S.
Jeff S. Checked in
Compressor was out on internal overload, windings would not close. Compressor needs to be replaced. Explained to homeowner that we will check the warranty and get back with them on pricing. Joel was out here on Saturday, callback. Lennox 14ACXS036-230A18 1915F22002
The Colony, TX 75056
Bob E.
Bob E. Checked in
The System is a 13 SEER R-22 System. The Horizontal Evaporator is frozen solid. The Furnace Blower Motor is Scalding Hot. The Common is open on the Blower Motor and the Capacitor is shorted. I believe the Blower will be fine after it cools off. It will take all night for the Evaporator to thaw. I explained the possibility of water on the ceiling when dealing with that much ice. I called the Management Company and explained the situation. They requested at my suggestion, I come back tomorrow. The Blower will have cooled off and the Evaporator will be thawed. They requested to pay the Bill all at once. I returned on Tuesday as promised and completed a thorough clean and service on both Systems. The Upstairs Blower Motor Capacitor was defective. I replaced the Capacitor and rechecked System operation. Everything appears to be functioning as expected. At this time. I collected payment by cc in full over the phone.
The Colony, TX 75056
Review
Joel was awesome - it’s SUNDAY and I got an immediate response, a text saying he was on the way with a picture. He had it fixed and up and running within 30 minutes!! It’s 100 degrees outside… NOTHING beats that level of service - and friendly people to boot - from the phone personnel to the service tech. I’m amazed, impressed - can’t recommend them MORE highly. It’s SO hot outside and I have some cool AC blowing!! Did I mention it’s Sunday evening?!! Wow!!
Vicki - The Colony, TX 75056
Joel S.
Joel S. Checked in
Run capacitor dead on the fan side. Remove defective part and installed new run capacitor. System came on and operating properly at this time.
The Colony, TX 75056
Review
Joel is amazing! Great service, workmanship and professional! Thanks Joel!
Jennifer - The Colony, TX 75056
Joel S.
Joel S. Checked in
No cool upstairs unit. Found condenser flat. No refrigerant in it. Weld it up leak that the lid rubbed in the discharge line and pulled vacuum on system. When I started up system compressor did not want to start. Run capacitor was low so I changed it out to a new turbo 200. Compressor Still would not start. Had to add hard start kit in order for it to turn over. Since compressor head overheated it took a long time for me to get it started. I had to call the compressor down four times before it would stay started. System seems to be operating properly.
The Colony, TX 75056
Bob E.
Bob E. Checked in
They sent the wrong TXV. I need a modulating TXV. The part they sent isn’t even on the list for this Air Handler. The System is maintaining 73 degrees. 70 at night. Celeste is ordering the correct part. I returned on Tuesday the 28th of June to replace the defective component. After installing the Metering Device I tested system operation and found everything to be functioning as expected. I had to reset the Fault Status Board 5 times to get it to clear the fault codes. The Control Board may also have to be replaced.
The Colony, TX 75056
Bob E.
Bob E. Checked in
The Customer’s modulating TXV is defective. Per Bob he did not charge anything because he did not do anything yet since he is still waiting on an answer from Joel about what part to order.
The Colony, TX 75056
Bob E.
Bob E. Checked in
We are hard at it today! If you need help just call. And we never charge overtime.
The Colony, TX 75056
Jeff S.
Jeff S. Checked in
Found contactors pitted not energizing compressor, replaced 40 amps contactors for upstairs system. Also system is low on R22, declined adding any refrigerant. Homeowner wants quote on new system for upstairs.
The Colony, TX 75056
Review
ok
Dean - The Colony, TX 75056
Jeff S.
Jeff S. Checked in
Found low voltage wires chewed up by rodents. Repaired wires at condenser. Everything is working fine. Also cleaned out Primary drain line, clogged up tripping float safety switch.
The Colony, TX 75056
Jeff S.
Jeff S. Checked in
Checked system draining. We explained to the home owner it's a plumbing issue he stated he will call a plumber. System drain installed correctly.
The Colony, TX 75056
Review
Francisco was awesome!! Called me and got details about the issue, came out quickly, got the issue resolved, fully checked to be sure it was working well, then explained exactly what he did. Couldn’t be better - WOW!!
Vic - The Colony, TX 75056
Francisco  S.
Francisco S. Checked in
Arrived to find safety switch tripped added quickblast and clear drain system cooling properly at this moment. Customer will pay Laura
The Colony, TX 75056
Review
Excellent service, communication and professionalism!!! Thank you for always being SO good and putting your customers first!!
Vicki - The Colony, TX 75056
Review
From start to finish - excellence! True focus on communication and keeping me informed about each step. Patient explanation along with quality service and workmanship!
Vicki - The Colony, TX 75056