Great Service
A. M. Yazdani - Keller, TX 76248
Sam was courteous and professional and explained his findings very well.
KellerTX76248 32.94-97.2275



Great Service
Aaron - Keller, TX 76248
I needed a second opinion, and glad I did. As I thought, I didnt need any additional repairs. The other service tech was probably working off commission.
KellerTX76248 32.9175-97.2




Samuel H.
Apon arrival checked in with customer the following are my findings Found the Units working properly however the bigger of the 2 is amping out bad electrically on the fan motor upstairs informed the customer about his options we are going to wait and see how it fares please see pictures attached and estimates Filter sizes 20x25x4 16x25×4

Samuel H.
Completed summer maintenance visit found everything working properly at this time only recommendation is continual maintenance and changing the filters to 4inc customer understands and will do so

Samuel H.
Upon arrival found Outside unit off Probably low vlot flotation device device remediated system is working properly

Justin S.
Last time I was here I found a leak a condenser and customers ended up getting two new systems . I did a walkthrough as well as the access maintenance for both . No recommendations at this time.

Joel S.
Called for water intrusion. Inspected the attic and found that a vent tube from the tankless hot water heater had fallen and made the sheet rock sag. It was directly below the unit in the attic. Found no broken PVC or leaks from the HVAC unit. Advise clients that I resecured vent tube so that it would not happen again and they need to contact a sheet rock contractor.

Justin S.
Flame sensor connection was slightly loose so I tightened and ran for 30 min and got no alarms .

Justin S.
Thermostat was getting error code for flame center not being detected. Found alot of build up on sensor (especially for a 2 year old one) I replaced the sensor and it's working.

Justin S.
Checked both heatpumps in heating ,cleaned condenser coils and changed filters . Inspected ducts for air leaks or restrictions and made sure no error codes had been displayed recently . I did find that the upstairs unit was running on emergency heat and when inspected outside unit I found what appeared to be refrigerant residue under reversing valve . I sprayed soap and saw some bubbles but it being so cold .y gauges didnt tell me much . Also got dark out so need to return to look into this issue more .

Justin S.
Replace OEM Control Board

Justin S.
Found bad control board . Need to buy oem replacement.

Justin S.
Found igniter to be bad , replaced with new igniter and verified system was operating correctly.

Justin S.
Found multiple pull air leaks on both systems and attic, the 3 ton is getting a 10 degree split temp (20 is what I'm looking for). Refrigerant pressures were indicating a restricted evaporator coil, high superheated and low subcool telling me not enough freon is making it back to the compressor from the evaporator coil. I also noticed the gas line does not have a sediment trap and there is no flat switch for the condensation.

Jeff S.
Arrived to find high voltage short inside of furnace electrical panel, tripping breaker. Repaired and secured electrical wires. Everything is operating properly at this time.

Bob E.
I was Dispatched to do a Post-Install Inspection. I spoke with the Homeowner and walked the job with her. I offered to set up her Thermostat to the internet. She declined for now. I asked if she needed any help with the Thermostat. She stated the Installers had done a great job showing her around her new equipment. I investigated the Master Bedroom temperature difference issue. I explained the ducts had not changed and so every individual duct has the same ability to move air as before the Equipment change out. The temperature difference is worse now than it was because overall the system is pulling down the rest of the house far better than before. This leaves the Master Suite with an unsatisfied Heat Load. We need to add a supply AND a return. Her Bedroom door is often closed and while closed there is no way for the air to get back out of the space causing a bottleneck. She acknowledges she has always had a temperature difference between the main house and the MST Bedroom. It is

Bob E.
The System is an old R-22 System that has been modified over the years. It is in extremely poor condition and should be replaced. The Customer is a friend of the Owners. I referred this to Russ.

Jeff S.
Performed spring maintenance check out on 3 systems. All system are way past life expectancy. Masterbedroom and upstairs systems are still functioning ok, but has lost lots efficiency. Downstairs compressor capacitor is weak and system is low on 410a refrigerant, recommended replacement of downstairs system. Homeowner will call and schedule comfort advisor.

Joel S.
HVAC inspection on residence. All prevalent notes are in the inspection forms

Jeff S.
Found upstairs game room condenser short cycling, because of low refrigerant. Repaired leak on hi pressure switch next to compressor. Pressurized with nitrogen, pulled vacuum and charge system with 11 pounds of 410a and 9 degree sub cooling. System is operating properly at this time.

Jeff S.
Completed maintenance on dual fuel heat pump systems, refrigerant levels, back up heaters are working. Run capacitors, start kits, compressor amps are operating fine No problems found at this time. Recommended adding Reme halo air purifier to system. Total price$995.00 parts/labor.

Francisco S.
Perform 3 system heat maintenance checked safety components checked co levels cleaned water off drain pan drain pan is rusted and need replacement. Cleaned flame sensors. System #2 isn’t heating found crack igniter Jason said he would have warranty company replAce it other 2 systems heating properly at this moment

Joel S.
AC performance tuneup times one system. Inspect blower, evaporator and ductwork. Ductwork is in bad shape. Some of it has the gray wrapper which means that they cannot be clean because they are so brittle. Checked the outdoor unit. Refrigerant level is a little high at this time. No damage will be done to the compressor though. I did not have a recovery cylinder to put the refrigerant back into. Check capacitors and contactors. Washed condenser coil. System is cooling properly at this time.

Francisco S.
Arrived to code 126 and cda rewired the high voltage one leg was loose and burn the wire nut system is operating at manufacturers specs at this moment.

Joel S.
AC performance tune up times two systems. Supply and change out both filters 1- 16 * 25 * 4 + 1- 20 * 25 * 4. Inspect blowers, evaporators and ductwork. Check thermostats for proper operations. Check outdoor unit. Refrigerant levels good on both units. Wash condenser coils. Systems operating at manufacturer specs at this time.

Jason D.
2 system Maintenance on trane units. Both condensers checked along with compressor Amps, fan amps, capacitors and hard starts. Both condensers were rinsed and pressures for units its will be attached to invoice. Both furnaces were checked, filters checked, blowers checked and the only issue found was with the drain lines.  Drains cover replacement and come with am ez trap. Can confirm ac is running at this time on all units.Â

Joel S.
AC performance tune up times one system. Inspect blower, evaporator and ductwork. System is a Zone with two thermostats. Treated drain line with white vinegar. Cast temperature drop. That was 18 degrees and we are looking for a 16 to a 20. Test thermostats for proper operations. Check outdoor unit. Refrigerant level good at this time. Test capacitor and contactor. Wash condenser coil. System operating at manufacturer specs at this time.