BOOK NOW

CONTACT

Call

CALL CONTACT BOOK NOW

Heating And Air Conditioning Keller TX

When you need expert comfort solutions in Keller, TX, whether it's HVAC repairs, indoor air quality services and more, AC Pros is the company for you! We're known for our commitment to professionalism and customer satisfaction.

Read our reviews to see why homeowners in Keller, TX are continuously happy with our team's skilled work.

Local Reviews
for Keller, TX

AC Pros Rated 5.0 out of 5 stars based on 1 customer reviews


Map of Keller, TX

Great Service




Review of AC Pros

I needed a second opinion, and glad I did. As I thought, I didnt need any additional repairs. The other service tech was probably working off commission.


Justin S.

Justin S.

Found multiple pull air leaks on both systems and attic, the 3 ton is getting a 10 degree split temp (20 is what I'm looking for). Refrigerant pressures were indicating a restricted evaporator coil, high superheated and low subcool telling me not enough freon is making it back to the compressor from the evaporator coil. I also noticed the gas line does not have a sediment trap and there is no flat switch for the condensation.

Near Harper Ct, Keller, TX 76248
Jeff S.

Jeff S.

Arrived to find high voltage short inside of furnace electrical panel, tripping breaker. Repaired and secured electrical wires. Everything is operating properly at this time.

Near Chase Oaks Dr, Keller, TX 76248
Bob E.

Bob E.

I was Dispatched to do a Post-Install Inspection. I spoke with the Homeowner and walked the job with her. I offered to set up her Thermostat to the internet. She declined for now. I asked if she needed any help with the Thermostat. She stated the Installers had done a great job showing her around her new equipment. I investigated the Master Bedroom temperature difference issue. I explained the ducts had not changed and so every individual duct has the same ability to move air as before the Equipment change out. The temperature difference is worse now than it was because overall the system is pulling down the rest of the house far better than before. This leaves the Master Suite with an unsatisfied Heat Load. We need to add a supply AND a return. Her Bedroom door is often closed and while closed there is no way for the air to get back out of the space causing a bottleneck. She acknowledges she has always had a temperature difference between the main house and the MST Bedroom. It is

Near Belaire Dr, Keller, TX 76262
Bob E.

Bob E.

The System is an old R-22 System that has been modified over the years. It is in extremely poor condition and should be replaced. The Customer is a friend of the Owners. I referred this to Russ.

Near Belaire Dr, Keller, TX 76262
Jeff S.

Jeff S.

Performed spring maintenance check out on 3 systems. All system are way past life expectancy. Masterbedroom and upstairs systems are still functioning ok, but has lost lots efficiency. Downstairs compressor capacitor is weak and system is low on 410a refrigerant, recommended replacement of downstairs system. Homeowner will call and schedule comfort advisor.

Near Hays Dr, Keller, TX 76248
Joel S.

Joel S.

HVAC inspection on residence. All prevalent notes are in the inspection forms

Near Jacob Ave, Keller, TX 76248
Jeff S.

Jeff S.

Found upstairs game room condenser short cycling, because of low refrigerant. Repaired leak on hi pressure switch next to compressor. Pressurized with nitrogen, pulled vacuum and charge system with 11 pounds of 410a and 9 degree sub cooling. System is operating properly at this time.

Near Spicewood Ct, Keller, TX 76248
Jeff S.

Jeff S.

Completed maintenance on dual fuel heat pump systems, refrigerant levels, back up heaters are working. Run capacitors, start kits, compressor amps are operating fine No problems found at this time. Recommended adding Reme halo air purifier to system. Total price$995.00 parts/labor.

Near Briar Meadow Dr, Keller, TX 76248
Francisco  S.

Francisco S.

Perform 3 system heat maintenance checked safety components checked co levels cleaned water off drain pan drain pan is rusted and need replacement. Cleaned flame sensors. System #2 isn’t heating found crack igniter Jason said he would have warranty company replAce it other 2 systems heating properly at this moment

Near Hays Dr, Keller, TX 76248
Joel S.

Joel S.

AC performance tuneup times one system. Inspect blower, evaporator and ductwork. Ductwork is in bad shape. Some of it has the gray wrapper which means that they cannot be clean because they are so brittle. Checked the outdoor unit. Refrigerant level is a little high at this time. No damage will be done to the compressor though. I did not have a recovery cylinder to put the refrigerant back into. Check capacitors and contactors. Washed condenser coil. System is cooling properly at this time.

Near Belaire Dr, Keller, TX 76262
Francisco  S.

Francisco S.

Arrived to code 126 and cda rewired the high voltage one leg was loose and burn the wire nut system is operating at manufacturers specs at this moment.

Near Meandering Woods Dr, Keller, TX 76248
Joel S.

Joel S.

AC performance tune up times two systems. Supply and change out both filters 1- 16 * 25 * 4 + 1- 20 * 25 * 4. Inspect blowers, evaporators and ductwork. Check thermostats for proper operations. Check outdoor unit. Refrigerant levels good on both units. Wash condenser coils. Systems operating at manufacturer specs at this time.

Near Meandering Woods Dr, Keller, TX 76248
Jason D.

Jason D.

2 system Maintenance on trane units. Both condensers checked along with compressor Amps, fan amps, capacitors and hard starts.  Both condensers were rinsed and pressures for units its will be attached to invoice. Both  furnaces were checked, filters checked, blowers checked and the only issue found was with the drain lines.   Drains cover replacement and come with am ez trap. Can confirm ac is running at this time on all units. 

Near Briar Meadow Dr, Keller, TX 76248
Joel S.

Joel S.

AC performance tune up times one system. Inspect blower, evaporator and ductwork. System is a Zone with two thermostats. Treated drain line with white vinegar. Cast temperature drop. That was 18 degrees and we are looking for a 16 to a 20. Test thermostats for proper operations. Check outdoor unit. Refrigerant level good at this time. Test capacitor and contactor. Wash condenser coil. System operating at manufacturer specs at this time.

Near Indian Knoll Trail, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Cole K.

Cole K.

Replaced motor and blade. System functioning properly at this time.

Near Meandering Woods Dr, Keller, TX 76248
Jason D.

Jason D.

: Heating Maintenance on 2 systems. Checked both stages of heating. Checked the heat exchangers. Cleaned the flame sensors and checked the igniters. Checked all the safety switches. Checked the gas pressures and checked for carbon monoxide. There is no carbon monoxide present at this time. Tightened all the electrical connections. Inspected the blower motors and the inducer motors. Inspected the ductwork. Replaced the 20x25x4 filters. The systems are working properly on heat mode at this moment. Outdoor Temperature: 55 Upstairs Blower Motor Amps: 4.78 Inducer Motor Amps: .46 Gas Pressure: good Igniter: 17 ohms Flame Sensor: clean Pressure Switches: good Heat Exchangers: good High Limit Switch: good Vent Pipe: good Carbon Monoxide: 0 ppm Filter: 20x25x4 Replaced today Downstairs Blower Motor Amps: 9.40 Inducer Motor Amps: .79 Gas Pressure: good Igniter: 15 ohms Flame Sensor: clean Pressure Switches: good Heat Exchangers: good High Limit Switch: good Vent Pipe: good Carbon Monoxide: 0 pp

Near Briar Meadow Dr, Keller, TX 76248
Joel S.

Joel S.

CDA plug had come loose from circuit board area near Drive. Plug back in and put unit in test mode. Added two pounds r410a to a chief 10° subcool. Need to order new condenser fan motor and blade for that unit. It has a wobble to it when compressor is at 100%. Office to call and schedule when part arrives

Near Meandering Woods Dr, Keller, TX 76248

A Family Owned Company

Dallas-Fort Worth — We You