Heating And Air Conditioning Keller TX
When you need expert comfort solutions in Keller, TX, whether it's HVAC repairs, indoor air quality services and more, AC Pros is the company for you! We're known for our commitment to professionalism and customer satisfaction.
Read our reviews to see why homeowners in Keller, TX are continuously happy with our team's skilled work.
Local Reviews
for Keller, TX
Our Reviews by City
Great service!
Ronna - Keller, TX 76248
Nick was a great technician!!!
KellerTX76248 32.93-97.21Great Service
A. M. Yazdani - Keller, TX 76248
Sam was courteous and professional and explained his findings very well.
KellerTX76248 32.94-97.2275Great Service
Aaron - Keller, TX 76248
I needed a second opinion, and glad I did. As I thought, I didnt need any additional repairs. The other service tech was probably working off commission.
KellerTX76248 32.9175-97.2Russ T.
Full heat tune up two systems. Upon arrival both systems were turned on in heat mode. The blower motor, burners, heat exchangers, flame sensors, safety switches, igniters, gas lines, vent systems, electrical connections, duct systems, and thermostats were all checked. The filters were changed with one's provided by the homeowner. Both systems are heating properly at this time.
Joel S.
Dispatch to find out the results of the air quality test that Sarah had performed. She believes it is the spray foam that she had installed and her attic. A documented pictures on the furnace area where it was pulling in attic air without being filtered. I opened up the furnace and documented pictures of the dirt and debris that has collected over the years. System is a 2007 American standard straight air conditioning. Gas heat. Outside is too large for the inside. Outside is a 60 inside is a 54. This is terms of BTUs that is used to calculate homes. I showed Sarah the results of the pictures and recommended that I sent her an estimate for a new complete 5 ton variable speed compressor.
Samuel H.
Replace thermostat under warranty system is working properly at this time new system was installed two months ago
Nicholas S.
Preformed system maintenance on up and Downstairs systems. Customer systems had dampers installed so I opened the duct leading to a bed room and slightly closed off to the main area where the thermostat is located. Both systems where very dirty and recommended the customer wash the condenser coils at the time of filter change. Also recommended norr frequently changing of the filters. Both systems refrigerant levels are good with an upstairs differential of 18 degrees and Downstairs of 17. The electrical readings where all in normal operating range. I did note a lot of sweating on the duct and plenum box, tracked the issue to a poor air seal on the system leaking cold air onto the warm metal causing the sweat. Customer approved seal and I taped and masticed the unit to prevent air leaks.
Joel S.
Dispatch to give a quote for an erv system. After I spoke with Sarah she stated that she smells like a chemical smell in the home in the afternoon when the air conditioner is running. In order to give the best customer service I'm going to wait until her results come in to decide what would be best moving forward for her benefit.
Joel S.
AC performance tuneup x 2 systems. Filters need to be changed out soon. Drains are clear and flowing. Systems are operating at manufacture specs at this time.
Samuel H.
Apon arrival checked in with customer the following are my findings Found the Units working properly however the bigger of the 2 is amping out bad electrically on the fan motor upstairs informed the customer about his options we are going to wait and see how it fares please see pictures attached and estimates Filter sizes 20x25x4 16x25×4
Samuel H.
Completed summer maintenance visit found everything working properly at this time only recommendation is continual maintenance and changing the filters to 4inc customer understands and will do so
Samuel H.
Upon arrival found Outside unit off Probably low vlot flotation device device remediated system is working properly
Justin S.
Last time I was here I found a leak a condenser and customers ended up getting two new systems . I did a walkthrough as well as the access maintenance for both . No recommendations at this time.
Joel S.
Called for water intrusion. Inspected the attic and found that a vent tube from the tankless hot water heater had fallen and made the sheet rock sag. It was directly below the unit in the attic. Found no broken PVC or leaks from the HVAC unit. Advise clients that I resecured vent tube so that it would not happen again and they need to contact a sheet rock contractor.
Justin S.
Flame sensor connection was slightly loose so I tightened and ran for 30 min and got no alarms .
Justin S.
Thermostat was getting error code for flame center not being detected. Found alot of build up on sensor (especially for a 2 year old one) I replaced the sensor and it's working.
Justin S.
Checked both heatpumps in heating ,cleaned condenser coils and changed filters . Inspected ducts for air leaks or restrictions and made sure no error codes had been displayed recently . I did find that the upstairs unit was running on emergency heat and when inspected outside unit I found what appeared to be refrigerant residue under reversing valve . I sprayed soap and saw some bubbles but it being so cold .y gauges didnt tell me much . Also got dark out so need to return to look into this issue more .
Justin S.
Replace OEM Control Board
Justin S.
Found bad control board . Need to buy oem replacement.
Justin S.
Found igniter to be bad , replaced with new igniter and verified system was operating correctly.
Justin S.
Found multiple pull air leaks on both systems and attic, the 3 ton is getting a 10 degree split temp (20 is what I'm looking for). Refrigerant pressures were indicating a restricted evaporator coil, high superheated and low subcool telling me not enough freon is making it back to the compressor from the evaporator coil. I also noticed the gas line does not have a sediment trap and there is no flat switch for the condensation.
Jeff S.
Arrived to find high voltage short inside of furnace electrical panel, tripping breaker. Repaired and secured electrical wires. Everything is operating properly at this time.
Bob E.
I was Dispatched to do a Post-Install Inspection. I spoke with the Homeowner and walked the job with her. I offered to set up her Thermostat to the internet. She declined for now. I asked if she needed any help with the Thermostat. She stated the Installers had done a great job showing her around her new equipment. I investigated the Master Bedroom temperature difference issue. I explained the ducts had not changed and so every individual duct has the same ability to move air as before the Equipment change out. The temperature difference is worse now than it was because overall the system is pulling down the rest of the house far better than before. This leaves the Master Suite with an unsatisfied Heat Load. We need to add a supply AND a return. Her Bedroom door is often closed and while closed there is no way for the air to get back out of the space causing a bottleneck. She acknowledges she has always had a temperature difference between the main house and the MST Bedroom. It is
Bob E.
The System is an old R-22 System that has been modified over the years. It is in extremely poor condition and should be replaced. The Customer is a friend of the Owners. I referred this to Russ.
Jeff S.
Performed spring maintenance check out on 3 systems. All system are way past life expectancy. Masterbedroom and upstairs systems are still functioning ok, but has lost lots efficiency. Downstairs compressor capacitor is weak and system is low on 410a refrigerant, recommended replacement of downstairs system. Homeowner will call and schedule comfort advisor.
Joel S.
HVAC inspection on residence. All prevalent notes are in the inspection forms
Jeff S.
Found upstairs game room condenser short cycling, because of low refrigerant. Repaired leak on hi pressure switch next to compressor. Pressurized with nitrogen, pulled vacuum and charge system with 11 pounds of 410a and 9 degree sub cooling. System is operating properly at this time.
Jeff S.
Completed maintenance on dual fuel heat pump systems, refrigerant levels, back up heaters are working. Run capacitors, start kits, compressor amps are operating fine No problems found at this time. Recommended adding Reme halo air purifier to system. Total price$995.00 parts/labor.