Heating And Air Conditioning Farmers Branch TX
When you need expert comfort solutions in Farmers Branch, TX, whether it’s HVAC repairs, indoor air quality services and more, AC Pros is the company for you! We’re known for our commitment to professionalism and customer satisfaction.
Read our reviews to see why homeowners in Farmers Branch, TX are continuously happy with our team’s skilled work.
Local Reviews
for Farmers Branch, TX
Our Reviews by City
Excellent service
Lab - Farmers Branch, TX 75244
Jason always gives above and beyond. Where ever he goes our business goes with him
Joel us the best!! Appreciate him so much.
Sue - Farmers Branch, TX 75234
Just takes care of business with kindness.
Jeff’s repair
Tom - Farmers Branch, TX 75234
Jeff was professional and gracious.
Professional, great work
Stephanie - Farmers Branch, TX 75234
Thank you! Great service. Also polite and knows his stuff.
Joel is the BEST
Ronnie - Farmers Branch, TX 75234
Excellent in every way.
Efficient, knowledgeable, honest
Stephanie - Farmers Branch, TX 75234
Great job servicing my AC today. Thank you!
Great service
Ronnie - Farmers Branch, TX 75234
The young men were so helpful and considerate.
Jason is great!
Tom - Farmers Branch, TX 75234
Jason was great! We have used AC Pro’s for years and he is the best tech ever. Would welcome back every time I we need service.
Thank you
Stephanie - Farmers Branch, TX 75234
Cole did a great job. He solved the problem we were having!

Jason D.
Arrived to find system not running from blown fuse. Fuse was replaced and when turned on contactors chattered. Tstat wire was unhooked and system was turned on again and ran. That wore was tested to see if anywhere touching then tstat was replaced. Due to time time constraints it couldn't be programed so ill.need to return tomorrow to finish it. System will also need a belt for the blower. Please call.jason with any questions. Replaced the belt and got system up and running. Still needs work which I'll have to address on Tuesday. Ac is cooling at this time.

Joel S.
AC performance tune up times three systems. Inspect blowers, evaporators and ductwork. Drains are flowing at this time. Refrigerant levels are good at this time. The system that controls the master bedroom is 30 years old. Sue has decided to go ahead and change it out. I have collected half of the full balance. 17,551 is the total. It will be going in on Thursday.

Russ T.
Performed to system, AC maintenance, replaced 20 x 25 x 4 air filters for the homeowner. Tightened all electrical connections at the indoor and outdoor equipment. Temperature split between the return and the supply was good. System for the right side of the house had high compressor start amps, recommended to homeowner that we install a 5 ton start assist kit to drop the amp draw under the LRA of a manufacturer. Homeowner Agreed to installing a start assist kit and compressor start amp draw is below LRA of manufactures all compressors, run load amps and start amps are within manufacturer specifications. As well as the fan motors amp draw capacitors are also within specs and rinsed condenser coils with water only set thermostats back to schedule.

Russ T.
Performed heat maintenance everything is working properly changed filter for $55

Joel S.
Filter was loose inside the filter grill bracket. Changed out filter and make sure it would not make any more noise

Justin S.
Wasnt flame sensor , was actually the zone board that I replaced . System now working properly.

Justin S.
Found flame sensor bad . Need to return with one tomorrow

Justin S.
Checked filters and fl as me sensors and verified inducer motors were running properly and flu pipes were connected . Checked condensation lines and performed a co test. The 2016 upflow had some gaps around plenum so I sealed it up for customer. Suggested and spoke about Remy halo benefits but not interested at the moment .

Justin S.
Performed heat PM on 3 units . Changed filters , checked flame sensors and ig lighters and checked for any error codes . Inspected flu pipes and the overall operation of these units in heat . None of them had float switches and the oldest one has had some condensation issues in past so I installed one float switch for now and she will get the others next time.

Bob E.
I was Dispatched to replace the cool and heat relays.

Bob E.
Universal blower motor I was Dispatched to replace a Blower Motor On a RTU. I (We , Justin and I) replaced the Blower Motor. After installing the Motor I discovered the Motor was constantly powered. I found the Heat Relay stuck closed and the Cooling Relay coil was shorted. I temporarily wired the Blower Motor to run constantly until we can bring back the correct relays. The A/C will cycle normally. We also repaired the Server Room A/C as well. The new transformer we open. A factory defect.

Joel S.
No cool on one of two units again. Found bad Transformer on other unit. Replaced with new and wash condenser coil. That system only controls the electrical room. It only has one duck from the rooftop unit to the electrical room. The part that controls the office has a bad blower motor. We are checking availability and price now.

Joel S.
No cool on two rooftop units. One unit had a defective contactor and transformer. The other unit is not sending power to the disconnect on the roof. Systems are 25 years old. Recommendations today are to get a maintenance on systems. Clients can contact us after power is restored so that we can check the 3-ton unit. 4 ton is cooling at this time. All three condenser coils are 85% impacted with dirt.

Jeff S.
East unit was not cooling, Replaced warranty 40/5 microfared everything is functioning ok.

Bob E.
Maintenance X 1 everything appears to be functioning as expected. At this time. The Customer wants to renew his MA in the Fall.

Jeff S.
Completed diagnostic, installed Turbo 70 microfared run capacitor, checked charge everything is functioning fine.

Jeff S.
Drains were clogged up tripping safety switch. Flushed drain line. Everything is up and running.

John h A.
Preform HVAC maintenance on one unit 410A system with two control thermostat, change also check system drain and filter. Homeowner supply there own indoor blower amps are .4, checked outdoor unit refrigerant level also amp draw on motor also compressor 7.5 motor amps are 1.0

Joel S.
AC performance tuneup x 3. All systems operating at MFG specs at this time.

Francisco S.
Perform 2 system AC maintenance washed both condensers tested capacitors and contactors changed customer supplied filter put right air flow setting for system controlling living room both systems cooling properly at this moment

Jeff S.
Completed one time maintenance, Recommended adding float safety switch to drain line. Also compressor Lock rotor rated amps at 117 starting up at 129, Recommended adding hard start kit to help out compressor on start up and Turbo run capacitor. Existing capacitor is very weak at this time. Also cleaned condenser coils. Homeowner will add start assist/Turbo capacitor and float safety switch to system. Will wait on maintenance contract. Turbo run capacitor/hard start kit $675.00 Float drain safety switch$210.00 Gold maintenance membership $235.00 1yr. Spring and fall check 15% 0ff parts.

Jeff S.
Installed T6 Honeywell thermostat, also replaced 16x25x4 media filter. Recommended Gold membership maintenance contract to service all systems, total cost would be $533.00 for 1 year and 15% off parts.

Jeff S.
Replaced furnace circuit control board, checked all operations everything is working great.

Jeff S.
Completed diagnostic, found relay on circuit control board sticking and that's keeping the fan energized. When both thermostats are not calling. Recommend replacing and ordering a new furnace circuit board. Need to call with quote on part/labor. Also can you check the warranty on board. Amana furnace GME80805DX 1308741721

Joel S.
Hot surface igniter faulty. Removed and installed universal. The inducer motor is making a noise which indicates the bearings are beginning to fail on it. I am going to send a quote for that part. Quote to replace OEM Inducer motor $519.36